Baker Tank Company / Altech


P.O. Box 40
Arp, Texas 75750
100 Hwy 64 East
(903) 859-2111


General Technical Specifications

The Altech IFR is an aluminum structure consisting of a series of interconnected hollow tubular pontoons surfaced with aluminum sheets. When landed, the IFR is supported on adjustable legs situated between pontoon sections and on 10' centers on the perimeter. The flat surface panels are laid out on a supporting gridwork of extrusions with the edges overlapped and clamped in a vapor tight metal-to-metal joint by an extruded butt strap and stainless steel fasteners. The peripheral seal is normally polyurethane closed cell foam. However, other materials are available as required. The seal is clamped in place with bolts and clamps to ensure a vapor-tight seal.

Installation Specifications

  1. Tank Access
    All ALTECH IFR components can be moved into a tank through a 20" manway. Special arrangements can be made for smaller or irregular tank openings.

  2. Installation Crews
    Installation work will be done by trained crews working under an experienced supervisor and will be in strict accordance with manufacturer's instructions.

Standard Features

  • Deck Manway/Vent (Vacuum relief device)
  • Column Negotiators, 24" Diameter wells
  • Roof-mounted combination air scoops/inspection hatches
  • Peripheral Seal
  • Gauging Unit
  • Grounding Cables
  • Anti-rotation system
  • Adjustable legs
  • Double strength ladder pad
  • Stainless Steel Leg Pads

Optional Equipment

  • Auto Gauge Float Well
  • Oversized column negotiators (to accommodate larger columns)
  • Center Vent on tank roof
  • Ladder Gauge Pipe Combination (aluminum or steel)
  • OSHA safety climbing devices for ladder
  • Gauge Pipe (aluminum or steel)
  • Floating suction lines
  • Tank modifications and repairs
  • Primary-Secondary seal combinations
  • Inlet line diffuser
  • Special seal materials
  • Walkways
  • Jet mixer baffles
  • Foam dams
  • Deck Drains
  • Other special accessories as required

Material Specifications

All material used in the manufacture of the ALTECH IFR will be new, first-quality materials manufactured and fabricated in accordance with applicable government and industry specifications.

  1. Surface Paneling
    Alloy - Alloy 3105
    Configuration - Flat coiled sheet
    Thickness - .020" x 60" wide
    Tensile Strength - 19,000 psi (minimum) Ultimate
    Note: .023", .032" thickness available as option (Allow 3004)
    Diagram

  2. Pontoons
    Shape - 8" or 10" diameter tubing
    Alloy - Alloy 3004 Series
    Thickness - .050" minimum
    Tensile Strength - 25,000 psi Ultimate

    End Caps - All Pontoons
    Alloy - Alloy 5052
    Configuration - Flanged plate
    Thickness - .100"
    Tensile Strength - 30,000 psi Ultimate
    Diagram

    End Brackets
    Alloy - Alloy 5052, 6061-T6
    Configuration - Welded double-gusseted
    Thickness - .125"
    Tensile Strength - 33,000 psi Ultimate

  3. Legs
    Alloy - Alloy 6063-T6, 6061-T6
    Configuration - 1 1/4" Sch.5 Pipe or 2" Sch.5 Pipe
    Tensile Strength - 30,000 psi (6063-T6) minimum
    Note: 300 Series SS Legs available as option
    Diagram

  4. Miscellaneous Extruded Parts
    Alloy - Alloy 6063-T6, 6061-T6
    Configuration as required - Extruded
    Tensile Strength - 30,000 psi Ultimate

  5. Seal, Peripheral
    (Materials may vary to suit the stored product and field conditions)
    Seals - Microcellular Closed Cell Urethane Wiper, Tapered 5/8" x 1/8" x 12" wide.

    Special Seals
    Extruded Closed Cell Buna-N (High Nitrile)
    Configuration - Tapered 1 1/2" x /2" x 12 1/2" wide.

    Extruded EPDM
    Configuration - Tapered 5/8" x 1/8" x 12" wide

    Surlyn® Wiper Seal
    Cross-linked lonomer Resin
    Configuration - Tapered 1 1/4" x 1" x 12 1/2" wide
    Special coated fabrics over flexible core to suit stored products or existing seals (i.e. Teflon, Viton, Butyl Rubber).
    All of the aforementioned seals available with matching secondary seal option.

  6. Fasteners
    1. Stainless Steel bolts and aluminum nuts at all structural points Grade 18-8
    2. Stainless Steel indented Hex Head tapping screws
    3. Appurtenances and other non-structural points (i.e. column negotiator plates, air valve and gauge unit.)

 

© 2005 Baker Tank Co. / Altech  |  Design by Visual Applications